The TMP 3-Way Mixing Panel’s primary application is as a single temperature mixing device where there are no flow requirements in the primary loop.

Intended to be used with DHW tanks as a heat source, the PLC is programmed with a 24hr timer for
potable applications. The TMP085DP not only allows for higher output, but it is also a 2-zone panel. So
even with a DHW heat source, you can now have two radiant floor zones. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible.

A DHW priority option for this panel is not available.

These panels can also be used as subpanels

Sequence of operation:

  • When the thermostat calls for heat, its internal 24V contacts close, the auxiliary terminals close, and the appropriate pump turns on.
  • As the pump moves fluid through the panel the thermostatic mixing valve adjusts the fluid temperature based on the user settings.
  • When the requirements of the thermostat are met, the internal contacts of the thermostat open, the auxiliary contacts open, and the corresponding pump(s) stops.
  • The pump is activated once every 24 hours, for 15 minutes, to ensure that potable water in the piping is not stagnant.

California Proposition 65 WARNING

Thumbnail Stk# Title Publication Date Size Download
Instructions
L6TMP000DP TMP085DP Panel Installation, Operation and Maintenance Manual (Instructions) 2021-10-01 10.51 MB Download
Submittal
SUBTMP000DP TMP - Dual Pump Panel Submittal 2021-09-24 2.27 MB Download
TMP085DP
Description Mechanical Electrical Detail Electrical Rough-in
TMP085DP Panel Schematic - Boiler, Dual Zone Radiant Heating
SCH-TMPDP-M003
Download:
PDF | Visio
SCH-TMPD-E003
Download:
PDF | Visio
SCH-MRIB-R001
Download:
PDF | Visio
TMP085DP Panel Schematic - Generic
SCH-TMPDP-M001
Download:
PDF | Visio
SCH-TMPD-E001
Download:
PDF | Visio
SCH-MRIB-R001
Download:
PDF | Visio
TMP085DP Panel Schematic - Boiler, Dual Zone Radiant Heating
SCH-TMPDP-M004
Download:
PDF | Visio
SCH-TMPD-E002
Download:
PDF | Visio
SCH-MRIB-R002
Download:
PDF | Visio
TMP085DP Panel Schematic - Hot Water Tank, Dual Zone Radiant Heating
SCH-TMPDP-M002
Download:
PDF | Visio
SCH-TMPD-E001
Download:
PDF | Visio
SCH-MRIB-R001
Download:
PDF | Visio

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer